Abstract

This study presents a simple NDT method with Ultrasonic Pulse Velocity (UPV) to detect repair of R/C columns by injection and grouting. In this paper, the technique applied is mainly based on the use of epoxy under pressure into the R/C column crack system for lightly damage, whereas grouting used for repair of medium and heavy damaged R/C columns. The specimen is initially charged to increase axial loads up to 0.1P0, 0.3P0 and 0.5P0. After repair, all specimens were retested with the same method. The test results show that the repair technique is in a good category with a pulse velocity value of 4.21km/s. Pulse velocity transmitter analysis provides conceptual support to increase column capacity through repair methods. Direct methods can be recommended for post-repair structural strength with high accuracy. This method is a potential candidate for future development, especially to predict the level of damage and building rehabilitation after an earthquake. © 2019 Published under licence by IOP Publishing Ltd.

Affiliations

Department of Civil Engineering, Beihang University, Beijing, China; Department of Civil Engineering and Planning, Yogyakarta State University, Yogyakarta, Indonesia; Departmen of Transportation Engineering and Science, Beihang University, Beijing, China; Department of Civil and Environmental Engineering, Universitas Gadjah Mada, Yogyakarta, Indonesia